Calibrating GSI audiometers and tympanometers

The ACS has built-in setups for 14 Grason-Stadler (GSI) instruments, and every one of them runs under full automatic control. Select the model, start the calibration, and the ACS sets each test point, measures it and adjusts the instrument to ANSI S3.6 and IEC 60645.

14GSI models with built-in setups
14 of 14Under full automatic serial / USB control
Under 10 minExhaustive calibration on most audiometers
ANSI & IECS3.6, IEC 60645, ISO 389 and S3.39 built in

Supported GSI models

Every GSI model the ACS calibrates

Automatic control means the ACS talks to the instrument through its serial or USB port: it sets frequency, level and channel itself and adjusts the instrument to the standard, and you only step in to change transducers.

ModelTypeControlWhat the ACS checks
Audiostar ProClinical audiometerAutomaticAir, bone and high frequency output levels, frequency, distortion, linearity, masking noise, tone switching, crosstalk, speech
GSI ArrowScreening audiometerAutomaticAir conduction output levels, frequency, distortion, linearity, tone switching
GSI-16Diagnostic audiometerAutomaticAir, bone and high frequency output levels, frequency, distortion, linearity, masking noise, tone switching, crosstalk, speech
GSI-17Screening audiometerAutomaticAir conduction output levels, frequency, distortion, linearity, tone switching
GSI-18Screening audiometerAutomaticAir conduction output levels, frequency, distortion, linearity, tone switching
GSI-37Tympanometer / middle ear analyzerAutomaticProbe tone level, compliance, probe pressure, reflex output level, distortion, linearity
GSI-38Tympanometer / middle ear analyzerAutomaticProbe tone level, compliance, probe pressure, reflex output level, distortion, linearity
GSI-39Audiometer and tympanometerAutomaticAudiometer output levels, frequency, distortion and linearity, plus probe tone level, compliance, pressure and reflex
GSI-61Clinical audiometerAutomaticAir, bone and high frequency output levels, frequency, distortion, linearity, masking noise, tone switching, crosstalk, speech
NovusABR / OAE instrumentAutomaticProbe and headset output level, distortion, intermodulation, linearity
PelloClinical audiometerAutomaticAir, bone and high frequency output levels, frequency, distortion, linearity, masking noise, tone switching, crosstalk, speech
Tympstar Version 1Tympanometer / middle ear analyzerAutomaticProbe tone level, compliance, probe pressure, reflex output level, distortion, linearity
Tympstar Version 2Tympanometer / middle ear analyzerAutomaticProbe tone level, compliance, probe pressure, reflex output level, distortion, linearity
Tympstar ProTympanometer / middle ear analyzerAutomaticProbe tone level, compliance, probe pressure, reflex output level, distortion, linearity

GSI model not listed? It can still be calibrated: set it up as a User Defined instrument with its own test configuration. See GSI on the full instrument list.

How it works

A GSI calibration, start to finish

  1. Select the GSI model

    The ACS loads the right calibration routine and sets the headphone type and impedance for that model.

  2. Connect and start

    Connect the instrument’s outputs to the ACS interface, and on automatic-control models its serial or USB port. The ACS steps through every test point, recording the values it found before any adjustment.

  3. Print the certificate

    Every result, the GSI and transducer serial numbers and the standard used, with your company logo. What a certificate should include.

ACS serial setup screen for automatic audiometer control

Questions

GSI calibration questions

Does the ACS adjust a GSI-61 by itself?

Yes. Under automatic control the ACS sets each test point on the GSI-61 and adjusts its output to the selected standard. The technician is only prompted to change transducers.

Can the ACS calibrate GSI tympanometers too?

Yes. The GSI-37, 38 and 39 AutoTymps and the TympStar V1, V2 and Pro are supported, with probe tone level, compliance, pressure and reflex tests to ANSI S3.39.

How often should a GSI audiometer be calibrated?

Under OSHA hearing conservation rules, an acoustic calibration at least yearly and an exhaustive calibration at least every two years. Calibration schedules.