Features & specifications

ACS specifications

Every ACS specification on one page. Download the two-page spec sheet to print or share, or print this page as it is. For photos, software features and model details, see the product overview.

System configurations

Models

ModelMicrophonesMastoidBest for
ACS 100 SA31 (Type 1)1Clinical audiometer and tympanometry calibration — laboratory-grade accuracy for hearing clinics and medical centers.
ACS 200 SA321Dual-microphone measurements, enhanced headphone verification and flexible instrumentation support.
ACS 600 SA361High-throughput laboratory, production and service environments that need multiple simultaneous measurement points.
ACS 102 SA3Type 2—Screening audiometer calibration with standard headphone measurement — a practical choice for screening programs.

Automatic control is available on the 73 audiometer models that support it (see the list). Audiometers that aren’t listed can be calibrated with a User Defined test configuration.

Test modes

Manual, user controlled or fully automatic.

Manual

You are prompted to set frequency, level and channel for each test point. The system provides audible feedback and waits for you to adjust the audiometer until it is within a user definable threshold before proceeding to the next test point.

User controlled

For supported audiometers with a USB, RS-232 or Bluetooth link: the system controls and adjusts the audiometer for each test point. You decide which test section to perform.

Fully automatic

For supported audiometers with a USB, RS-232 or Bluetooth link: the system controls and adjusts the audiometer for a full battery of tests. You are only prompted to change transducers.

Specifications

Accuracy

Frequency range
20 Hz to 22,000 Hz
Frequency accuracy
< ±1.0 Hz
Frequency uncertainty
0.11 Hz95% confidence level, k=2
Amplitude accuracy
< ±0.2 dB
Amplitude uncertainty
0.05 dB95% confidence level, k=2
Distortion
< 0.20 % @ 125 Hz
Crosstalk
< –80 dBr
Linearity test limits
+120 HL to –10 HL
Sound level measurement
Class 1Meets or exceeds ANSI S1.11-2004

Test coverage

Tests

Audiometer acoustic testsOutput level, distortion, narrowband noise, white noise, speech noise, speech level
Audiometer electrical testsFrequency, distortion, off level, rise time, fall time, overshoot, crosstalk, linearity, warble, pulse, SISI
Tympanometer testsProbe output level and distortion, compliance, pressure, reflex output level, distortion, narrowband level, switching (rise/fall/overshoot/off), linearity
Auditory Brainstem Response (ABR)Both probe and ABR headset: output level, distortion, intermodulation, linearity
Otoacoustic Emissions (OAE)Probe output level, distortion, intermodulation, linearity
Other testsHandswitch test, room acoustic levels (1/3 octave)

Compatibility

Transducers, couplers & mastoids

Transducers supported Headphones: TDH-39/39P, TDH-49/49P, TDH-50/50P, DD45, Beyer DT48, Holmco 8103, Sennheiser HAD-280, Sennheiser HDA 200, Sennheiser HDA 300, Radioear DD450, Radioear DD65v2, Oscilla H210A, DD45 Mono Masking, Auditdata CA1, SA1 Insert phones: EAR 2, EAR-3A, EAR-5A, IP30, CIRR-22 Insert Masking Phone, Danavox Single Insert, EARtone ABR Earcups, IP30 Insert Masking, ER-3c, Auditdata IN1 High frequency phones: Sennheiser HDA-200, HDA-280, HDA-300, Koss HV/1A, Kross R80, Radioear DD65v2, Holmco 9501, Auditdata CA1, CA1-HF Bone oscillators: Radio Ear B-71, B-81, Oticon A20 (forehead or mastoid position), Auditdata BC1 Probes: IOW Probe, IOWA Probe, OWA Probe, SnapPROBE, manufacturer provided, custom probe Contralateral phones: Telephonics TDH-39/39P, TDH-49/49P, TDH-50/50P, Radioear DD45, DD65, Eartone 3A, 5A, Danavox Insert Phone, IP30, Button Phone, CIR Contra Phone, custom contra
Couplers supported Headphones: NBS-9A/IEC-60303/IEC-60318-3, IEC-60318-1 Insert phones: IEC-126/HA-2/DB-0138, IEC-711, HA-1 High frequency phones: IEC 60318-2 Type 1 and IEC 60318-2 Type 2
Artificial mastoids supportedACS-M1, B&K-4930, Larson Davis AMC493 (AMC493 support includes temperature and humidity compensation). Flexible support for custom mastoids.
Free field optionsDegrees of incidence (0/45/90)

Compliance

Standards

Audiometry ANSI S3.6: 1969, 1989, 1996, 2004, 2010, 2018, 2025 IEC 60645 with ISO 389: 2002, 2012, 2017 Manufacturer factory specifications: Grason-Stadler, Interacoustics (2018 and 2025)
TympanometryANSI S3.39 (1987, 2007), IEC 60645-5
Room acousticsANSI S3.1 (2008), OSHA
MeasurementMeets or exceeds ANSI S1.11-2004 for Class 1 sound level meters
What these standards specify for an audiometer

Hardware & software

Inputs, interfaces & software

PC interfacesUSB for the ACS data acquisition system. USB, RS-232 or Bluetooth for audiometer control.
System inputs ACS 100: Microphone input, Audiometer Left, Audiometer Right, Transducer Left, Transducer Right, Bone Oscillator In, Bone Oscillator Out, Mastoid input, Handswitch/Continuity input ACS 200: Same as the ACS 100, with separate left and right microphone inputs ACS 600: Microphone Left and Right, Audiometer Left and Right, and Headphone Left and Right for each of the headphone, insert phone and high frequency phone stations, plus Mastoid input, Bone Oscillator In, Bone Oscillator Out and Handswitch/Continuity
DatabaseMicrosoft Access format with Customer, Audiometer and Calibration Data tables. Flexible import and export, multipage calibration certificates, and calibration reports for customer and audiometer management. The database can sit on a network drive and be shared by several systems.
Signal analyzerTone, noise and click measurement modes with real-time spectrum and time series plots
Other toolsContinuity test